MediLytic Ammonia Reagent Kit
MediLytic Ammonia Reagent Kit
Rs. 1,000.00
Couldn't load pickup availability
đ§Ș MediLytic Ammonia Reagent â 10 ml
Category: â Biochemistry Reagent
[Ammonia (NHâ) â UV Kinetic Method]
â Designed for quantitative estimation of Ammonia (NHâ) in serum and plasma
â Based on the UV Kinetic Enzymatic Method
â High accuracy with rapid kinetic measurement
â Suitable for routine clinical biochemistry laboratories
â Compatible with semi-auto and fully automatic biochemistry analyzers
đ§Ź Test Principle
â Based on the UV Kinetic Enzymatic Method
â Ammonia reacts with α-ketoglutarate in the presence of Glutamate Dehydrogenase (GLDH) and NADPH
â NADPH is oxidized to NADPâș during the reaction
â The decrease in absorbance at 340 nm is directly proportional to the ammonia concentration in the sample
đ§« Analyte Measured
â Ammonia (NHâ)
𩞠Sample Type
â Serum
â EDTA Plasma
â Heparin Plasma
â±ïž Reaction / Reading Time
â Rapid UV kinetic reaction
â Reading as per analyzer or manual protocol
đŠ Kit Contents
â Reagent 1 (R1) â 1 Ă 8 ml
â Reagent 2 (R2) â 1 Ă 2 ml
â Standard â 1 Ă 1 ml
â Pack Size: 10 ml
đŻ Key Advantages
â High sensitivity and precision
â UV kinetic enzymatic method for reliable results
â Ready-to-use reagents
â Excellent reproducibility and stability
â Suitable for routine and emergency laboratory testing
â Compatible with most clinical chemistry analyzers
đ§âïž Recommended For
â Diagnostic Laboratories
â Hospitals & Clinics
â Pathology Laboratories
â Medical Colleges & Teaching Laboratories
â Research Laboratories
đ§ Storage & Stability
â Store at 2â8°C
â Do not freeze
â Protect from direct sunlight
â Stable until the expiry date when stored as recommended
â ïž Important Notes
â For In-Vitro Diagnostic (IVD) use only
â For professional laboratory use only
â Samples should be processed promptly to avoid falsely elevated ammonia levels
â Results should always be interpreted along with clinical findings and other laboratory investigations
â Why Use This Reagent?
â Assists in the diagnosis and monitoring of hyperammonemia
â Useful in evaluating liver dysfunction and hepatic encephalopathy
â Supports the diagnosis of urea cycle disorders and inherited metabolic diseases
â Helps monitor critically ill patients with altered ammonia metabolism
â° When to Use This Test?
â Suspected hepatic encephalopathy
â Acute or chronic liver disease evaluation
â Investigation of unexplained neurological symptoms
â Assessment of metabolic disorders in infants and adults
â Routine biochemical investigations as recommended by clinicians
đ·ïž Why Choose MediLytic?
â Trusted biochemistry reagents for clinical laboratories
â Consistent quality and dependable performance
â Manufactured under stringent quality standards
â Designed for Indian laboratory conditions
â Delivers fast, accurate, and reliable diagnostic results